Physical Status |
Form Factor | Proprietary (Deep miniITX) |
Dimensions | 6.7"x 8.2" |
Processor System |
CPU | supports AMD EPYC™ 7002 Series Processors
|
Socket | 1 Socket SP3 (LGA4094) |
Chipset | System on chip |
System Memory |
Capacity | 4 DDR4 288pin DIMM slots (1DPC) |
Type | DDR4 RDIMM/ LRDIMM/ NVDIMM |
DIMM Size Per DIMM | RDIMM: 64GB, 32GB, 16GB, 8GB LRDIMM: 256GB, 128GB, 64GB 256GB is to be validated |
DIMM Frequency | RDIMM: 3200/2933/2666/2400MHz LRDIMM: 3200/2933/2666/2400MHz |
Voltage | 1.2V |
Expansion Slot |
PCIe 4.0 x 16 | SLOT 7: PCIe 4.0 x16 |
M.2 | 1 Mkey (PCIe4.0 x4/SATA); Form factor: 2280 |
TPM |
TPM support | TPM2S |
Storage |
SATA Controller | AMD EPYC™ Processors: supports 16 SATA 6Gb/s from 2 Slimline supports 1 SATA 6Gb/s M.2 |
Slimline for U.2 | 2 Slimline (PCIe 4.0 x8 or 8 SATA 6Gb/s) 4 Slimline (PCIe 4.0 x8) |
Ethernet |
Additional GbE Controller | 1 Intel® X550AT2: 2 RJ45 (10 GbE) |
LAN Controller | 1 RJ45 Dedicated IPMI LAN port |
Management |
BMC Controller | ASPEED AST2500 |
IPMI Dedicated GLAN | 1 Realtek RTL8211E for dedicated management GLAN |
Graphics |
Controller | ASPEED AST2500 |
Rear Panel I/O |
VGA Port | 1 DB15 |
USB 3.2 Gen1 Port | 2 Type A |
Lan Port | 2 RJ45 (10GbE) |
Dedicate LAN | 1 RJ45 |
UID Button/UID LED | 1 |
Internal Connector |
COM Header | 1 |
Auxiliary Panel Header | 1 (9pin): chassis intrusion, system fault LED, LAN activity LED |
TPM Header | 1 (13pin, LPC) |
Thermal Sensor Header | 1 |
IPMB Header | 1 |
PMBus CONN | 1 |
Fan Header | 3 (4pin) |
HDD PWR | 1 (4pin, 12V and 5V) for using 12V DCin PSU |
USB 2.0 Header | 1 (support 2 USB2.0) |
NMI Header | 1 |
System Panel | 1 (9pin): power switch, reset switch, system power LED, HDD activity LED |
Speaker Header | 1 |
BMC_SMB Header | 1 |
Power Connector | 1 (4pin, ATX PSU signal and 5Vsb), 2 (8pin, ATX 12V) support 12V DCin |
Clear CMOS | 1 (contact pads) |
Onboard LED |
Standby PWR LED 5vsb | 1 |
Fan Fail LED | 3 |
System BIOS |
BIOS Type | 256Mb SPI Flash ROM |
Hardware Monitor |
Temperature | CPU, TRMB_IN, TRMB_OUT1 temperature sensing |
Fan | Fan Tachometer CPU Quiet Fan (Allow Chassis Fan Speed AutoAdjust by CPU Temperature) Fan MultiSpeed Control |
Voltage | 1.8VSB,3VSB,5VSB,1.8V,3V,5V,12V,BAT,VCPU,VSOC,VCCM ABCD,VCCM EFGH |
Support OS |
OS | Microsoft® Windows: Server 2016 (64bit) Server 2019 (64bit) Linux: RedHat Enterprise Linux Server 8.2 (64bit) / 7.9 (64bit) CentOs 8.2 ( 64 bit) / 7.9 ( 64 bit) SUSE SLES 15.2(64 bit) / 12.5(64bit) UBuntu 20.04.1 (64 bit) /18.04.5 (64 bit) / 16.04.7 (64 bit) Hypervisor: VMWare® ESXi 6.7 u3 / 7.0 u1 vSphere 6.7 u3 / 7.0 u1 CITRIX Hypervisor 8.1.0 |
Environment |
Temperature | Operation temperature: 10°C ~ 35°C / Non operation temperature: 40°C ~ 70°C |